AEM
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by McFeters, G A
Right arrow Articles by Egozy, Y
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by McFeters, G A
Right arrow Articles by Egozy, Y
Agricola
Right arrow Articles by McFeters, G A
Right arrow Articles by Egozy, Y

 Previous Article  |  Next Article 

Appl Environ Microbiol. 1993 May; 59(5): 1410-1415

Distribution of bacteria within operating laboratory water purification systems.

G A McFeters, S C Broadaway, B H Pyle and Y Egozy

Department of Microbiology, Montana State University, Bozeman 59717.

ABSTRACT

Experiments were conducted to measure communities of bacteria within operating ultrapure water treatment systems intended for laboratory use. Samples from various locations within Milli-Q Plus and Milli-Q UV Plus systems were analyzed for populations of planktonic bacteria at weekly intervals over 3 months of operation. Relatively high initial densities of planktonic bacteria (10(2) to 10(3) bacteria per ml) were seen within both units when they were challenged with source water of poor quality, although the product water continued to be acceptable with regard to bacterial numbers, resistivity, and endotoxin concentration. Under more normal operating conditions, significant differences were seen in planktonic populations throughout the systems with excellent product water quality. A great deal of variability was observed in biofilm populations analyzed from various system surfaces after 3 months of operation. The concentrations of planktonic bacteria and biofilm densities were much lower in the unit containing a UV lamp. These findings suggest that a range of microenvironmental conditions exist within purified water systems, leading to variable populations of bacteria. However, product water of excellent quality was obtained despite the bacterial communities.


Appl Environ Microbiol. 1993 May; 59(5): 1410-1415