Previous Article | Next Article ![]()
Appl Environ Microbiol. 1968 December; 16(12): 1872-1874
Copyright © 1968 American Society for Microbiology. All Rights Reserved.
Central Research Laboratories, Ralston Purina Company, St. Louis, Missouri 63199
ABSTRACT
The application of polyvalent H serology for screening certain feed components for Salmonella was evaluated. In a comparative study of 1,894 suspicious or known positive samples, Salmonella organisms were detected in 1,141 samples with the conventional method and in 1,134 samples with the polyvalent H method. A statistical analysis of the results obtained by both methods indicated that the polyvalent H method is as reliable as the conventional method. Salmonellae can be detected by this method within 60 hr, whereas conventional methods require at least 4 days. The speed and reliability of the polyvalent H method are desirable for routine quality assurance.
| J. Bacteriol. | Microbiol. Mol. Biol. Rev. | Eukaryot. Cell | All ASM Journals |
|---|